Leadgene Leadgene
Anti-Human Red Blood Cell Antibody
Katalognummer

LDG0140YA

Weitere Dokumente
Paket & Preis werden geladen...
  • Übersicht

    Beschreibung

    Human anti-Human Red Blood Cell Antibody recognize to Red Blood Cells (RBC)

    Produktnotiz

    Recommended dilution factor:
    ELISA: 1:5000-20000

    Note: Working dilution for specific application should be determined by the investigator to obtain the best conditions.

  • Spezifikationen
    • Klonalität

      Recombinant Human IgG

      Isotyp

      IgG1

    • Klonname

      Human IgG

      Reaktivität

      Human

    • Anwendung

      ELISA, CLIA, LFIA

      Konjugation

      Unconjugated

    • Konzentration

      2 mg/mL

      Lagerpuffer

      Phosphate Buffered Saline containing 0.1% ProClin 300, pH 7.4.

    • Spezifität

      Red Blood Cells (RBC)

      Form

      Liquid

  • Anleitung
    • Versand

      The product is shipped with polar packs. Upon receipt, store it immediately at -20°C or lower for long term storage.

      Stabilität & Lagerung

      This product is stable after storage at:

      • 2-8°C for 2 weeks under sterile conditions from date of receipt.
      • -20°C or -80°C for 12 months under sterile conditions from date of receipt.

      Avoid repeated freeze/thaw cycles.
      Suggestion: Divide antibody into several vials. Keep only vials for usage at 2-8°C.

  • Bild
    Background interference observed in rapid tests run with different volumes of whole blood samples, comparing conditions with and without pretreatment using Anti-Human Red Blood Cell Antibody (Anti-RBC Ab). A significant reduction in background interference is observed in rapid test strips pretreated with Anti-Human Red Blood Cell Antibody when used to test whole blood samples, in contrast to non-pretreated strips.

    Background interference observed in rapid tests run with different volumes of whole blood samples, comparing conditions with and without pretreatment using Anti-Human Red Blood Cell Antibody (Anti-RBC Ab).
    A significant reduction in background interference is observed in rapid test strips pretreated with Anti-Human Red Blood Cell Antibody when used to test whole blood samples, in contrast to non-pretreated strips.

    1
    /
    1
    Gesamt   (1)
  • Bewertung

    Helfen Sie anderen, mehr über dieses Produkt zu erfahren. Nutzen Sie den Link unten, um Ihre Erfahrung zu teilen.

  • Publikation

    Derzeit gibt es keine Publikationen. Nutzen Sie den Link unten, um uns zu informieren.

  • Datenblatt & Dokumente
    MSDS
    Handbuch
    1
    /
    1

Haftungsausschluss:For Research Use or Further Manufacturing Only.

Diese Website verwendet Cookies wie in unserer Privacy Policy beschrieben, um Ihre Nutzererfahrung zu verbessern und Ihnen maßgeschneiderte Werbung anzubieten. Klicken Sie auf „Ich stimme zu", um zuzustimmen und fortzufahren.